TECHNICAL DATA
Standard Specification:
8mm OD. inlet pipe.
Inlet pressure test point.
Injector pressure test point.
Oxy pilot system.
Remote control option.
Safety thermocouple.
Autolight device.
Variable, minimum and maximum flow rates.
|
INJECTORS
Natural Gas: Multi-hole pattern
LPG: Multi-hole pattern
Operating Gas Pressures:
Natural Gas: 8" Wg, 20 mbar.
LPG: 14" Wg, 37 mbar.
|
GAS INPUTS:
|
Natural Gas |
LPG |
|
Input |
Output |
Input |
Output |
16" |
7.0kw |
3.2kw |
6.9kw |
3.5kw |
18" |
7.2kw |
3.7kw |
8.0kw |
4.3kw |
|
Installation Requirements
A clean well constructed Class 1 Flue of not less than ?? inches ID. Permanent Ventilation where
necessary. Gas supply at appropriate pressures. Non-combustible Base & Hearth. Installation
only by competent persons and in accordance with all relevant building and gas regulation.
|